Page 262 - Rules of Navigation2020
P. 262

Measurement of Deck Spaces:
                    A- Vessels with one tier of superstructures only:

                    (1) Poop, bridge, forecastle:
                                            (1)
                    The following exemptions   are allowed under certain conditions:
                       a)  Such length of the poop measured from the inside of the stern timber, at half height of
                                                           Th
                          the said poop, shall be equal to 1/10  of the full length of the ship.
                       b)  The portion of the bridge in way of the light and air spaces of the engine and boiler
                          spaces is being understood that such light and air spaces are not considered to extend

                          beyond the forward  bulkhead  of the stoke-hold  and the after  bulkhead of the main
                          engine-room.
                       c)  Such length of the forecastle measured from the inside of the stern at half height of the

                                                           th
                          said forecastle, shall be equal to 1/8   of the full length of the ship.
                       d)  In each of  the above  three cases of superstructures,  such  portions  as are in  way  of

                          corresponding openings in the sides of the ship, not provided with any means of closure
                    (2) Poop and bridge combined, or forecastle and bridge combined:
                                                                           (1)
                    In each of these combined spaces, the following exemptions   are allowed under certain
                    conditions:
                       a)  That length which corresponds only to the openings of the engine-room and boiler

                          spaces as specified in (1b) above.
                       b)  Such portions as are in way of corresponding openings not provided with any means

                          of closing in the sides of the ship.
                    (3) Shelter-decks:

                    In the case of shelter-decks. The following exemptions are allowed under certain conditions:
                       a)  The  portions  in  way  of  corresponding  openings  in  the  side  plating  of  the  ship  not
                          provided with any means of closing.

                       b)  Such  air  spaces  as are  situated  within  the  shelter-decks  must  be  measured  into  the
                          engine-room space and deducted together with 75% of their volume.

                    B- Vessels having more than one tier of superstructures:
                       1)  The exemptions Prescribed in paragraph A - (1), (2) and (3) above are applicable to the

                          lowest tier only.
                       2)  Tiers above the lowest tier, are only allowed the exemption   of such portions as are
                                                                                  (1)
                          in way of corresponding openings in the side plating of the vessel not provided with
                          any means of closure.



                    1  ) See (Art. 92 – B p. 177)
                                                            -210-
   257   258   259   260   261   262   263   264   265   266   267